Inverter Rated Motor?
|
 |
NEMA Frame Size?
|
"C" Face (Flange)?
|
 |
Nema Ratings?
|
ALL OUR MOTORS ARE INVERTER RATED
3,600 RPM Inverter Rated Motor 10:1
Enclosure: TEFC, Nema 4X, IP 65 (Washdown)
Frame: 1 HP: 143TC / 1.5, 2 and 3HP: 145TC / 5 HP: 184TC / 7.5hp: 213-72
Phase: 3-Phase 60 Hz
HP range: 1 HP to 7.5 HP
Input power: 208-230/460 VAC
Service Factor: 1.15
Insulation: Class F
Mounting: C-face- rigid base, footed
*Centrifugal pumps do not qualify for free shipping.
*Please call for shipping cost
Inverter Rated Motor?
“Inverter Rated” motors are suitable for use with Variable Frequency Drives and can run at very slow speeds without overheating, also they are capable of withstanding higher voltage spikes without their insulation failing. For this reason, an inverter-Rated motor can be much more expensive than general purpose motors.
Inverter Rated 10:1 means that the slowest speed at which the motor is expected to operate.
Example:
If you have a 3,500 rpm motor (60hz) the slowest speed must be 350 rpm (3500/10 = 350)
What Do The NEMA Frame Sizes?
The National Electrical Manufacturers Association (NEMA) is a US Manufacturers Organization which actively promotes standardized product specifications for electrical apparatus. NEMA frame size refers to mounting including the frame, motor and shaft dimensions. Is commonly used in the industry to ensure that replacement parts will fit and be readily available and that motors from different manufacturers will be interchangeable.
"C" Face (Flange)
This is the most popular type of face mounted motor is a type of flange used with close coupled pumps, speed reducers, and similar applications where the mounting holes in the flange are threaded to receive bolts. Normally the “C” flange is used where a pump or similar item is to be overhung on the motor. C flanges motors always have mounting holes in the face of the motor.
What Do The NEMA Ratings Mean?
The National Electrical Manufacturers Association (NEMA) is a US Manufacturers Organization which actively promotes standardized product specifications for electrical apparatus. NEMA establishes the performance criteria for enclosures intended for specific environments.
Type 1
Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts and to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt).
Type 2
Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
Type 3
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.
Type 3R
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure
against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.
Type 3S
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and for which the external mechanism(s) remain operable when ice laden.
Type 3X
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure.
Type 3RX
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that will be undamaged by the external formation of ice on the enclosure that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure.
Type 3SX
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion; and for which the external mechanism(s) remain operable when ice laden.
Type 4
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow,splashing water, and hose-directed water);and that will be undamaged by the external formation of ice on the enclosure.
Type 4X
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure
against ingress of solid foreign objects (windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure.
Type 5
Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and settling airborne dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
Type 6
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during occasional temporary submersion at a limited depth); and that will be undamaged by the external formation of ice on the enclosure.
Type 6P
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during prolonged submersion at a limited depth); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure.
Type 12
Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
Type 12K
Enclosures constructed (with knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure
against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water
Type 13
Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress
of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light
splashing); and to provide a degree of protection against the spraying, splashing, and seepage of oil and non-corrosive coolants.
*Centrifugal pumps do not qualify for free shipping.
*Please call for shipping cost
Shipping:
NOTE: Customer is responsible for: Removing the shipment from the truck (when applied), bringing it into your location, and noting damaged or missing items on the carrier's delivery receipt.
• Orders for “in-stock” items will normally ship the same day or next day
For International buyers: Please contact us, includes Alaska, Hawaii, and Puerto Rico. Customer is responsible for clearing customs and all associated fees. We won't under-value merchandise.
• All orders are shipped prepaid.
• The address must be in a commercial area and someone must be at the site to receive deliveries during normal business hours.
• We will apply shipping company’s fees for any problem with delivery caused by the customer error.
• Many carriers cannot deliver to P.O. Boxes but we can offer shipments via the United States Postal Service.
• Rural businesses are sometimes considered residential
• Any delivery time stated by the Company shall be treated as an estimate only. While every effort will be made to dispatch goods on time, no liability can be accepted by the Company for failure to deliver within the advertised times. The Company shall not be liable for any loss or damage whatsoever (including consequential loss of profit or revenue) arising directly or indirectly from any delay on the delivery of all or any of the goods and services, howsoever caused.